Model 1000 Gas Analyzer

Available in CO2 or H2S versionsReadily Field Replaceable SensorsSimple Operation and Field CalibrationStandard Outputs: 4-20 mA, RS-485, 3 Relays Non-Hazardous area rated

OLCT 10 – OLC 10 Toxic & Flammable Gas Fixed Detector

4-20 mA output analog transmitter without displayAvailable with catalytic bead, electrochemical or semi-conductor sensorsDetects combustible, toxic and refrigerant gases (CO, NO, NO2, Methane, Propane, Butane, Hydrogen, LPG, NGV and freons) - EN 14624 compliant with regards to R134a monitoringFor commercial use (boiler rooms, hospitals)

OLCT 100 – OLC 100 Toxic and Combustible Gas Detector

4-20 mA analog transmitter without displaySIL2 capability for LEL, O2, CO, H2S, NH3, CO2Detects combustible, toxic or refrigerant gases and O2Available with electrochemical, infrared or semi-conductor sensorsDesigned for industrial applicationsAvailable in explosion-proof or intrinsically safe versions, and stainless steelA high-temperature version allows operation up to 200°C

OLCT 10N Fixed Digital Gas Detector

NEW! Discover the preconfigured pack with cable : Easy DuoDigital transmitter without displayAvailable with catalytic bead or electrochemical sensorsDetects O2, combustible gas, and toxic gasesAvailable for detection of O2, CO2, H2S, NH3, NO, NO2, Methane, Propane, Butane and HydrogenFor commercial and light industrial applications (laboratories, cooling rooms, hospitals, boiler rooms, waste water treatment plants, etc.)

OLCT 20 – OLC 20 Fixed Gas Detector

Designed for indoor or outdoor monitoringComplete reliabilityCan be fitted on a housing with a M25 or 3/4” NPT threadStainless steel detector provides protection and resistance to corrosive agentsThe precalibrated sensors can be disconnected by turning the head of the unit

OLCT 60 Industrial Gas Detector

4-20 mA analog transmitter with displayDetects O2, combustible, toxic and refrigerant gasesCorrosion resistantDesigned for industrial applicationsAvailable with remote sensor head, flameproof or intrinsic safety versionsNon-intrusive, one-man calibrationXP IR infrared sensor for combustible gases or CO2

OLCT 80 Fixed Gas Detector

Frequency 2.4 GHz (EU) / 900 MHz (USA)Low Power RequirementUp to 3 km Line-of-Sight RangeRobust Mesh Network TopologyUp to 49 devices per networkFlexible Input/Output options(analog, on/off, Modbus RS485)

SafEye (Quasar 900) – Open Path Combustible Gas Detector

Multi-combustible gas detectionRange of 200 metersLow maintenance costsEasy detector communicationEasy configuration and troubleshootingAutomatic heated opticsBuilt-in event recorderStainless steel constructionLong warranty